Sub-Zero Refrigerator Sealed System Repair
THE CLIENT REPORTED THAT THEIR SUB-ZERO REFRIGERATOR WAS NOT MAINTAINING COLD TEMPERATURES. DIAGNOSTIC TESTING IDENTIFIED A FREON LEAK IN THE SEALED SYSTEM. THE TECHNICIAN PERFORMED A FULL SYSTEM REBUILD INCLUDING REPLACEMENT OF THE COMPRESSOR, EVAPORATOR, FILTER DRIER, AND HEAT EXCHANGER. THE SYSTEM WAS VACUUMED, RECHARGED WITH R134A, PRESSURE TESTED, AND CLEANED. THE UNIT WAS RESTORED TO FULL COOLING FUNCTION. REPAIR TIME: 5 HOURS.
Viking Ice Maker Replacement
AFTER A POWER OUTAGE, THE CLIENT'S VIKING REFRIGERATOR’S ICE MAKER STOPPED FUNCTIONING. THE TECHNICIAN IDENTIFIED A FAULTY ICE MAKER UNIT AND REPLACED IT WITH A MANUFACTURER-APPROVED PART. THE NEW UNIT WAS INSTALLED AND TESTED TO ENSURE PROPER ICE PRODUCTION. THE CLIENT WAS ADVISED TO USE A SURGE PROTECTOR TO PREVENT FUTURE DAMAGE. REPAIR TIME: 40 MINUTES.
Viking Refrigerator Control Board Replacement
THE CLIENT REPORTED COOLING ISSUES IN THEIR VIKING REFRIGERATOR. UPON INSPECTION, THE CONTROL BOARD WAS FOUND TO BE DAMAGED DUE TO OVERHEATING. THE TECHNICIAN REPLACED THE CONTROL BOARD WITH A NEW ORIGINAL PART, CALIBRATED THE SYSTEM, AND TESTED IT FOR STABLE TEMPERATURE CONTROL. THE ISSUE WAS RESOLVED AND MAINTENANCE ADVICE WAS GIVEN. REPAIR TIME: 1.5 HOURS.
Sub-Zero Freezer Freon Leak Repair
THE CLIENT’S SUB-ZERO FREEZER WAS NOT COOLING PROPERLY. A FULL SEALED SYSTEM FAILURE WAS DIAGNOSED. THE TECHNICIAN PERFORMED A COMPLETE REBUILD INCLUDING COMPRESSOR, EVAPORATOR, HEAT EXCHANGER, AND SYSTEM RECHARGE WITH APPROVED REFRIGERANT. ALL COMPONENTS WERE TESTED AND VERIFIED FOR FUNCTIONALITY. COOLING WAS FULLY RESTORED. REPAIR TIME: 7 HOURS.
Wolf Oven Igniter Replacement
THE CLIENT REPORTED IGNITION FAILURE ON THEIR WOLF OVEN. THE TECHNICIAN FOUND TWO IGNITERS WERE MALFUNCTIONING. BOTH WERE REPLACED WITH ORIGINAL MANUFACTURER PARTS. THE SYSTEM WAS TESTED THROUGH MULTIPLE HEAT CYCLES TO ENSURE SAFE AND RELIABLE OPERATION. PREVENTIVE MAINTENANCE TIPS WERE PROVIDED. REPAIR TIME: 1 HOUR.
THE CLIENT REPORTED THAT ONE SECTION OF THEIR WOLF OVEN WAS NOT HEATING. UPON INSPECTION, THE TECHNICIAN IDENTIFIED A BURNED CONTROL BOARD THAT WAS PREVENTING THE HEATING ELEMENT FROM ACTIVATING. THE DEFECTIVE BOARD WAS REPLACED WITH A NEW MANUFACTURER-APPROVED COMPONENT. THE UNIT WAS TESTED AND VERIFIED TO BE FULLY OPERATIONAL. REPAIR TIME: 1.5 HOURS.
THE FRIDGE COMPARTMENT OF A SUB-ZERO REFRIGERATOR WAS FAILING TO MAINTAIN PROPER TEMPERATURE. THE TECHNICIAN FOUND THAT THE EVAPORATOR FAN MOTOR IN THE LOWER SECTION WAS MALFUNCTIONING, DISRUPTING AIRFLOW. A NEW FAN WAS INSTALLED, RESTORING NORMAL COOLING FUNCTION. POST-REPAIR MONITORING CONFIRMED STABLE PERFORMANCE. REPAIR TIME: 40 MINUTES.
Wolf Oven Igniter Replacement
THE CLIENT REPORTED HIGH TEMPERATURES IN BOTH SECTIONS OF THEIR VIKING REFRIGERATOR. DIAGNOSTIC TESTING REVEALED A FREON LEAK IN THE SEALED SYSTEM. THE TECHNICIAN PERFORMED A COMPLETE SYSTEM REBUILD INCLUDING COMPRESSOR, EVAPORATOR, DRYER, AND SERVICE VALVES. AFTER RECHARGING WITH R134A AND TESTING FOR LEAKS, THE UNIT RETURNED TO NORMAL OPERATION. REPAIR TIME: 5 HOURS.
THE CLIENT REQUESTED GENERAL MAINTENANCE FOR THEIR SUB-ZERO BI SERIES REFRIGERATOR. THE TECHNICIAN PERFORMED A FULL SYSTEM INSPECTION, CLEANED THE CONDENSER COILS, AND REPLACED BOTH THE AIR AND WATER FILTERS. THE UNIT WAS FOUND TO BE OPERATING NORMALLY AFTER SERVICE AND NO FAULTS WERE DETECTED. REPAIR TIME: 40 MINUTES
Refrigerator stopped cooling
THE VIKING REFRIGERATOR HAD COMPLETELY STOPPED COOLING. INVESTIGATION REVEALED THAT THE RELAY BOARD HAD FAILED, CUTTING POWER TO THE COMPRESSOR. THE FAULTY CONTROL COMPONENT WAS REPLACED WITH A NEW BOARD. COOLING FUNCTION RESUMED IMMEDIATELY AND THE SYSTEM STABILIZED WITHIN THE EXPECTED TIMEFRAME. REPAIR TIME: 1 HOUR.